Temptress DIY Kit - Specifications

 

BTU Output

Given the flexibility that the system provides, you can adjust the air conditioner to meet your unique needs by varying both the compressor and evaporator fan speed. Below is a table that is representative of how the system will perform given three different scenarios.  Please note that in order to test the system, we had to direct the four evaporator ports into a single plenum with a 4" hole on the other side.  It was the only way to have a consistent way to measure the airflow and BTU.  But, it did increase the return pressure.  Thus, your mileage may vary.

Test Output Compressor watts Evap watts Evap CFM Water GPM Water temp BTU Supply temp Supply RH Return temp Return RH Total watts
Low Output 64.7 6.48 52 2.5 88 1430 90.4 57.8% 74.9 84.8% 89.16
Med Output 180.04 19.29 88 2.5 88 3070 90.5 57.8% 73.5 82.6% 221.84
High Output  255.6 72.33 160 2.5 88 4090 90.0 58.4% 76.4 80.0% 397.46

Size and Weight

 Item Height Width Depth Weight (lbs) Comments
Compressor 6” 4.5” 2.7” 3.79 Hi and low pressure tubes extend to 9.5”
Compressor Driver Board 1.16” 4” 3.10” .26

 

Evaporator 5.7 16 13 8.10
Fan Speed Controller 1.6 2.2 5 .3 As viewed from the knob facing you
Voltage Converter 1.5 2.88 4.10 1.1 As viewed from wires facing you
Thermostat 1.7 3.1 1.34 .2 As viewed from the front of the screen
Condensor 3 10 11.5 1.65 As viewed from outlets facing you
Potentiometer .88 1.03 1.65 .03 As viewed from the knob facing you
Filter/Dryer 1.75 4.28 1.75 .44
Pump 3.25 8 1.86 1.16 Pump outlet facing up
Relay 1.75 1.43 3.10 .21 As viewed from wires facing you

 

Electrical Specifications

Item Voltage Min watts Max watts Typical watts Min gauge wire Fuse Comments
Evaporator 12V 6.48 73 19 14 gauge 10A The evaporator and pump are protected by the 15A fuse
Pump 12V 10.8 14.4 N/A 18 gauge 3A Not adjustable. The amount of watts consumed depends on the head pressure
Relay - switched side 12V N/A N/A N/A 12 gauge 15A Provides power to evaporator and pump
Compressor 24V 64 255 180

14 gauge 

Protected by 12V voltage converter fuse

Power requirements will vary based on pressure, state of charge, temperatures, etc.
Voltage Converter 12V to 24V 12V N/A N/A N/A 12 gauge 30A Provides 24V to compressor and driver board
Thermostat 5V N/A N/A N/A 18 gauge .5A Not adjustable

 

Water Pump Pressure and Capacity

We use a high qualify marine magnetic drive pump.  The Inlet/Outlets are 5/8".

Back pressure (feet) Flow (GPM) Watts
3.3 4.0 14.4
4.9 3.2 13.2
6.6 1.9 10.8